| Kode Produk | ATV610C13N4 |
| Brand | Schneider |
| Kategori | Drives & Starters |
Pengiriman ke seluruh Indonesia via ekspedisi terpercaya
| Range of product | Altivar ATV610 |
|---|---|
| Product specific application | Fan, pump, compressor, conveyor |
| Product or component type | Variable speed drive |
| Device short name | ATV610 |
| Variant | Standard version |
| Product destination | Asynchronous motors Synchronous motors |
| Mounting mode | Cabinet mount |
| EMC filter | Integrated conforming to IEC 61800-3 category C3 with 50 m |
| IP degree of protection | IP00 |
| Type of cooling | Forced convection |
| Supply frequency | 50...60 Hz +/-5 % |
| Network number of phases | 3 phases |
| [Us] rated supply voltage | 380...460 V - 15...10 % |
| Motor power kW | 132 kW for normal duty 110 kW for heavy duty |
| Motor power hp | 200 hp for normal duty 150 hp for heavy duty |
| Line current | 237 A at 380 V (normal duty) 203.8 A at 460 V (normal duty) 201 A at 380 V (heavy duty) 174.2 A at 460 V (heavy duty) |
| Prospective line Isc | 50 kA |
| Apparent power | 162.4 kVA at 460 V (normal duty) 138.7 kVA at 460 V (heavy duty) |
| Continuous output current | 250 A at 2.5 kHz for normal duty 211 A at 2.5 kHz for heavy duty |
| Maximum transient current | 275 A during 60 s (normal duty) 317 A during 60 s (heavy duty) |
| Asynchronous motor control profile | Variable torque standard Optimized torque mode Constant torque standard |
| Output frequency | 0.1…500 Hz |
| Nominal switching frequency | 2.5 kHz |
| Switching frequency | 1...8 kHz adjustable |
| number of preset speeds | 16 preset speeds |
| Communication port protocol | Modbus serial |
| Option card | Slot A: communication card, Profibus DP V1 Slot A: digital or analog I/O extension card Slot A: relay output card |
| Output voltage | <= power supply voltage |
|---|---|
| Motor slip compensation | Automatic whatever the load Adjustable Can be suppressed Not available in permanent magnet motor law |
| Acceleration and deceleration ramps | S, U or customized Linear adjustable separately from 0.01 to 9000 s |
| Braking to standstill | By DC injection |
| Protection type | Thermal protection: motor Motor phase break: motor Thermal protection: drive Overheating: drive Overcurrent between output phases and earth: drive Overload of output voltage: drive Short-circuit protection: drive Motor phase break: drive Overvoltages on the DC bus: drive Line supply overvoltage: drive Line supply undervoltage: drive Line supply phase loss: drive Overspeed: drive Break on the control circuit: drive |